This Part has options, please click the button below to order.
543-300008 Closed Cooling System
This closed cooling Front Mount Half system kit fits Volvo , OMC - 5.0 L Ford , 5.8 L Ford - engines from the years 1989 | 1990 | 1991 | 1992 | 1993. This cooling system kit cools the block only.
NOTE: Please have Year, Engine Size, Engine Model and Serial Number available when ordering or making inquiries on this closed cooling system
|
|
This Part has options, please click the button below to order.
543-300136 Closed Cooling System
This closed cooling Front Mount Half system kit fits Volvo , OMC - 7.4 L - engines from the years 1994 | 1995 | 1996 | 1997. This cooling system kit cools the block only.
Front Mount Block Only EFI/GL cooling system kit
NOTE: Please have Year, Engine Size, Engine Model and Serial Number available when ordering or making inquiries on this closed cooling system
|
|
This Part has options, please click the button below to order.
543-300819 Closed Cooling System
This closed cooling Front Mount Half system kit fits Volvo , OMC - 7.4 L - engines from the years 1998. This cooling system kit cools the block only.
Front Mount Block Only, MPI
Also fits 1999 7.4LPWTR GiMPI
NOTE: Please have Year, Engine Size, Engine Model and Serial Number available when ordering or making inquiries on this closed cooling system
|
|
This Part has options, please click the button below to order.
543-400085 Closed Cooling System
This closed cooling Front Mount Half system kit fits Volvo , OMC - 7.4 L - engines from the years 2000. This cooling system kit cools the block only.
Front Mount Block Only, GI. V-Belt only (not serpentine belt).
NOTE: Please have Year, Engine Size, Engine Model and Serial Number available when ordering or making inquiries on this closed cooling system
|
|
This Part has options, please click the button below to order.
543-500429 Closed Cooling System
Volvo 225 / 260 - 1985-1993, Front Mount Block Only PS cooling system kit. SJE V103 | Half Front Mount
NOTE: Please have Year, Engine Size, Engine Model and Serial Number available when ordering or making inquiries on this closed cooling system
|
|
This Part has options, please click the button below to order.
543-500214 Closed Cooling System
Volvo 7.4L - 1994-1997, Half-System Alternator mounted lower on engine (see 300819 if alternator in front of port head) | Half Front
NOTE: Please have Year, Engine Size, Engine Model and Serial Number available when ordering or making inquiries on this closed cooling system
|
|
This Part has options, please click the button below to order.
543-605416 Compact-A exchangers are single pass on the shell side Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions. This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material
|
|
This Part has options, please click the button below to order.
543-605416cn Compact Type A, size:4 x 16, 1348 sq in, copper-nickel tubes Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions.
This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material, and held in position with stainless steel clamps (sold separately). All exchangers are supplied with a zinc anode.
All Raw Water and Coolant connections are beaded hose connections. Other styles and dimensions are available on request. Connection configurations may also be specified to meet your individual system requirements.
Compact Type A; size:4 x 16; 1348 sq in, copper-nickel tubes
|
|
This Part has options, please click the button below to order.
543-605420 Compact-A exchangers are single pass on the shell side Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions. This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material
|
|
This Part has options, please click the button below to order.
543-605420cn Compact Type A, size:4 x 20, 1763 sq in, copper-nickel tubes Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions.
This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material, and held in position with stainless steel clamps (sold separately). All exchangers are supplied with a zinc anode.
All Raw Water and Coolant connections are beaded hose connections. Other styles and dimensions are available on request. Connection configurations may also be specified to meet your individual system requirements.
Compact Type A; size:4 x 20; 1763 sq in, copper-nickel tubes
|
|
This Part has options, please click the button below to order.
543-605424 Compact-A exchangers are single pass on the shell side Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions. This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material
|
|
This Part has options, please click the button below to order.
543-605424cn Compact Type A, size:4 x 24, 2178 sq in, copper-nickel tubes Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions.
This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material, and held in position with stainless steel clamps (sold separately). All exchangers are supplied with a zinc anode.
All Raw Water and Coolant connections are beaded hose connections. Other styles and dimensions are available on request. Connection configurations may also be specified to meet your individual system requirements.
Compact Type A; size:4 x 24; 2178 sq in, copper-nickel tubes
|
|
This Part has options, please click the button below to order.
543-605520 Compact-A exchangers are single pass on the shell side Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions. This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material
|
|
This Part has options, please click the button below to order.
543-605520cn Compact Type A, size:5 x 20, 2605 sq in, copper-nickel tubes Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions.
This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material, and held in position with stainless steel clamps (sold separately). All exchangers are supplied with a zinc anode.
All Raw Water and Coolant connections are beaded hose connections. Other styles and dimensions are available on request. Connection configurations may also be specified to meet your individual system requirements.
Compact Type A; size:5 x 20; 2605 sq in, copper-nickel tubes
|
|
This Part has options, please click the button below to order.
543-605524 Compact-A exchangers are single pass on the shell side Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions. This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material
|
|
This Part has options, please click the button below to order.
543-605524cn Compact Type A, size:5 x 24, 3237 sq in, copper-nickel tubes Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions.
This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material, and held in position with stainless steel clamps (sold separately). All exchangers are supplied with a zinc anode.
All Raw Water and Coolant connections are beaded hose connections. Other styles and dimensions are available on request. Connection configurations may also be specified to meet your individual system requirements.
Compact Type A; size:5 x 24; 3237 sq in, copper-nickel tubes
|
|
This Part has options, please click the button below to order.
543-605528 Compact-A exchangers are single pass on the shell side Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions. This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material
|
|
This Part has options, please click the button below to order.
543-605528cn Compact Type A, size:5 x 28, 3869 sq in, copper-nickel tubes Compact-A exchangers are single pass on the shell side, 3 pass on the tube (raw water) side. These exchangers have no expansion tank integrated into their design, and rely instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions.
This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material, and held in position with stainless steel clamps (sold separately). All exchangers are supplied with a zinc anode.
All Raw Water and Coolant connections are beaded hose connections. Other styles and dimensions are available on request. Connection configurations may also be specified to meet your individual system requirements.
Compact Type A; size:5 x 28; 3869 sq in, copper-nickel tubes
|
|
This Part has options, please click the button below to order.
543-606416 Compact-B exchangers are designed for mounting off the engine Compact-B exchangers are designed for mounting off the engine, in a vertical or horizontal position. They are designed as single pass on the shell and three pass on the tube side. Hose connections are oriented to one side for ease of routing from an exchanger mounted on the deck or bulkhead. No expansion tank is incorporated in the exchanger, relying instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions. This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material
|
|
This Part has options, please click the button below to order.
543-606416cn Compact Type B, size:4 x 16, 1348 sq in, copper-nickel tubes Compact-B exchangers are designed for mounting off the engine, in a vertical or horizontal position. They are designed as single pass on the shell and three pass on the tube side. Hose connections are oriented to one side for ease of routing from an exchanger mounted on the deck or bulkhead. No expansion tank is incorporated in the exchanger, relying instead on an external expansion tank or an overflow recovery bottle to capture coolant volumes which exceed system capacity in operation, and return them to the cooling system when it cools down. Coolant is added to the system via a separately mounted fill neck with pressure cap. The shell is completely packed with tubing, providing the maximum heat transfer surface possible for each set of external dimensions.
This exchanger is illustrated without a mounting bracket. We have mounting brackets for virtually any mounting configuration. The exchanger is mounted on the bracket with cushioning material, and held in position with stainless steel clamps (sold separately). All exchangers are supplied with a zinc anode.
All Raw Water and Coolant connections are beaded hose connections. Other styles and dimensions are available on request. Connection configurations may also be specified to meet your individual system requirements.
Compact Type B; size:4 x 16; 1348 sq in, copper-nickel tubes
|
|